Enabling & Configuration of Auto Tracking
Looking for some help for enabling and configuration of auto tracking for a Dahua Hubble? Look no further!
Setting up auto tracking for DH-PSDW81642MP-H-A360-E9-D440 is a breeze when following along to the steps provided. This will include setting up presets, configuration of IVS rules, calibrating the PTZ & Panoramic Cameras for Auto Tracking, and finally enabling Auto Tracking & testing.
To enable smart plan, set IVS rules & presets and calibration & enable auto tracking of the PTZ, follow the steps below:
- Login to the camera and find the location you want to track targets from
- Navigate to the “Smart Plan” menu by clicking the “Settings” tab
- Click “Event” from the list along the left side of the screen & select “Smart Plan”
- Select the “IVS” Icon and click “Save”
- Now click on the “IVS” from the left hand side list
From here you can draw your rule, being either a Tripwire or an Intrusion Zone. We’ll demonstrate using an Intrusion Zone:
- Draw rule on the small preview screen. You can double click the preview screen to enlarge it & adjust any points you have set
- When happy with any adjustments, double click screen again to go back to preview screen
- You can set active periods for any rules set from this menu. We’ll keep ours active 247/7 for the demonstration
- These actions will trigger when target crosses / appears within the threshold set
- Set the direction of where targets trigger from. Either by entering / exiting the area, or both
- Enable “Smart Track” by clicking the check box
- Click Save when you are happy with your settings
To calibrate the panoramic and PTZ Cameras, please follow the steps below:
- Select “Smart Track” from the left hand menu
- Click the green “+” to add calibration point & adjust each point on each preview screen. So they are placed in the same areas of the live feed
- Select the save icon to save each calibration point
- You will need at least 4 calibration points for each of the four areas marked 1,2,3 & 4
- Click Area 2 & continue calibrating until all 4 areas have at least 4 calibration points
When you’re happy with your calibration, you’ll need to enable Alarm Track:
- Click Alarm Track Tab, select “Enable” check box & turn “Auto Track” on
- Set Track Time, Idle Time and PTZ Idle Position to whatever you see fit
- Ensure you click “Save” whenever you are done
How to set up preset positions for the PTZ:
- Click “PTZ Settings” from the left hand side menu and select “Preset” from the list that appears to the right of the preview window
- Select “+ Add” to add preset option. Name it, use the PTZ controls to position the PTZ in the scene you want to cover & click save
- You can click each saved preset to make sure the PTZ will orientate itself to the correct position for that preset